BORNIT® Slurry EL 2C
sealing | mineral-based | area in contact with soil | terrace | balcony | water tanks
- 2-component, pressure waterproof, flexible sealing slurry
- sulphate-resistant, open to vapour diffusion
- under tiles and surface pavements indoors and outdoors
- coating of concrete elements
- high compressive strength and abrasion resistance
- store dry, cool but frost-free
- can be stored for 12 months in originally closed containers
Clean tools with water quickly after use.
BORNIT® Slurry EL 2C is not suitable for waterproofing against water loads acting on the rear.
- seam- and jointless sealing
- waterproofing against ground moisture, non-pressing and pressing water
- also suitable for damp substrates
- crack-bridging
- for sealing the positive and negative side against pressing water
- sulphate resistant
- waterproofing remains open to diffusion
- easy to process
soil moisture and non-pressing water: 2 mm dry layer thickness = 3.4 kg / m²
splash water on the wall plinth: 2 mm dry layer thickness = 3.4 kg / m²
Product data in brief
BZM 2 (mixture)
In case of doubt, please contact the BORNIT® application technology department or the BORNIT® service hotline on +49 375 2795 123.
The product illustrations are to be understood as examples. No legally binding claim can be derived from them. We reserve the right to make changes to the product’s appearance.
Our packaging complies with the relevant legal requirements and with Regulation (EU) 2025/40 on packaging and packaging waste (PPWR). The technical documentation in accordance with Annex VII is available and can be provided on request by email to info@bornit.de.
® Slurry EL 2C, waterproofing, mineral-based, flexible, sealing slurry, splash water">
® Slurry EL 2C, waterproofing, mineral-based, flexible, sealing slurry, splash water">0761
BORNIT-Werk Aschenborn GmbH
Reichenbacher Straße 117
08056 Zwickau / Germany
2013
6900002694/2025
EN 1504-2:2004: ZA.1d and ZA.1e
surface protection product – coating, protection against penetration of substances (1.3), moisture management (2.2)
| Linear shrinkage | NPD |
| Thermal expansion coefficient | NPD |
| Cross-cut test | NPD |
| CO² permeability | sD ≥ 200 m |
| Water-vapour permeability | sD = 21.2 m (Class II) |
| Capillary water absorption and water permeability | w = 0.016 kg/m2 x h0.5 |
| Freeze-thaw resistance with de-icing salt impact | No cracks, bubbles, detachment / adhesive strength MW = 1.5 N/mm² (kEW = 1.2 N/mm²) |
| Resistance against temperature shock | NPD |
| Resistance against chemicals | NPD |
| Crack-bridging capability | A 2 |
| Tear-off test for assessment of adhesive strength | MW = 1.4 N/mm² (kEW = 1.2 N/mm²) |
| Fire behaviour | Class Efl |
| Grip | NPD |
| Artificial weathering | NPD |
| Antistatic behaviour | NPD |
| Adhesive strength on wet concrete | NPD |
| Hazardous substances | see product safety data sheet |
UFI 7X20-D07K-9007-A127
- How much: as exact a quantity as possible
- Who: Age, weight, sex and condition of the person(s) concerned.
- When: Time of the event
- Where: Place of occurrence
- How: ingestion, inhalation, skin contact, etc.
Component A
H318: Causes serious eye damage.
H335: May cause respiratory irritation.
P102: Keep out of reach of children.
P260: Do not breathe dust/fume/gas/mist/vapours/spray.
P280: Wear protective gloves/protective clothing/eye protection/face protection/hearing protection.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310: Immediately call a doctor.